Mercury Wetted Relay HGSR application and selection guide
Mercury wetted relays provide stable low contact resistance and extremely low or bounce-free switching behavior for specialized precision measurement and test applications where signal integrity is critical.
Use this family where bounce performance and contact stability are more important than a general-purpose relay solution. Confirm orientation, regulatory and application limits before production use.
Key selection parameters
- Series
- HGFR / HGMR / HGSR / HVR and related families
- Switching behavior
- Low bounce and stable contact resistance
- Signal type
- Precision signal, pulse and test switching
- Orientation
- Series-dependent; confirm mounting requirement by datasheet
- Compliance note
- Mercury handling/application suitability must be confirmed for the target market
Before choosing a model
These notes keep product pages useful for engineers while avoiding overclaims. Final ratings remain model- and application-specific.
Mercury wetted relay series comparison
Use this table to choose the starting series before checking the individual model datasheet for coil, contact form, orientation and regulatory suitability.
| Series | Best fit | Switching behavior | Selection focus |
|---|---|---|---|
| HGFR | Fast precision signal switching | Low bounce mercury wetted contact | Confirm coil voltage, contact form and mounting orientation |
| HGMR | Measurement and instrumentation switching | Stable low contact resistance | Confirm signal level, life requirement and package constraints |
| HGSR | Sensitive / compact mercury relay applications | Repeatable low-level switching | Confirm footprint, orientation and environmental limits |
| HVR / related | Higher voltage precision switching | Family-specific ratings | Check datasheet before replacing with general reed relay |
Representative models in this family
Each model links to its own detail page and datasheet/RFQ path. Use the All Models index for the complete list.
- Coil Voltage: 12 VDC
- Min Breakdown Voltage: 4K VDC
- Max Carrying Current: 5A
- Series: 2 channel 4kv
- Coil Voltage: 12 VDC
- Min Breakdown Voltage: 4K VDC
- Max Carrying Current: 5A
- Series: 1 channels 3kv
- Coil Voltage: 12VDC
- Min Breakdown Voltage: 2K VDC
- Max Carrying Current: 5A
- Series: 1 channels 2kv
- Coil Voltage: 24 VDC
- Min Breakdown Voltage: 4K VDC
- Max Carrying Current: 5A
- Series: 2 channels 4kv
- Coil Voltage: 24 VDC
- Min Breakdown Voltage: 4K VDC
- Max Carrying Current: 5A
- Series: 1 channels 3kv
- Coil Voltage: 24VDC
- Min Breakdown Voltage: 2K VDC
- Max Carrying Current: 5A
- Series: 1 channels 2kv
- Coil Voltage: 5VDC
- Min Breakdown Voltage: 4K VDC
- Max Carrying Current: 5A
- Series: 2 channels 4kv
- Coil Voltage: 5VDC
- Min Breakdown Voltage: 4K VDC
- Max Carrying Current: 5A
- Series: 1 channels 3kv
- Coil Voltage: 5VDC
- Min Breakdown Voltage: 2K VDC
- Max Carrying Current: 5A
- Series: 1 channels 2kv
- Series: HGFR / HGMR / HGSR / HVR and related families
- Switching behavior: Low bounce and stable contact resistance
- Signal type: Precision signal, pulse and test switching
- Orientation: Series-dependent; confirm mounting requirement by datasheet
- Series: HGFR / HGMR / HGSR / HVR and related families
- Switching behavior: Low bounce and stable contact resistance
- Signal type: Precision signal, pulse and test switching
- Orientation: Series-dependent; confirm mounting requirement by datasheet
- Series: HGFR / HGMR / HGSR / HVR and related families
- Switching behavior: Low bounce and stable contact resistance
- Signal type: Precision signal, pulse and test switching
- Orientation: Series-dependent; confirm mounting requirement by datasheet
Mercury Wetted Relay HGSR selection FAQ
Answers are shown on-page to match the structured FAQ data and help engineers prepare datasheet review or RFQ requests.
How do I choose a Mercury Wetted Relay HGSR model?
Start from the application requirement, then compare Series, Switching behavior, Signal type, Orientation, Compliance note. Open the model detail page and PDF datasheet before confirming the final ordering code.
Where can I find individual datasheets for this product family?
Each representative model card links to its own detail page and PDF datasheet. For production projects, submit an RFQ so voltage, current, mounting and compliance requirements can be confirmed.
What information should be included in an RFQ?
Include working voltage, current, load type, contact or output form, coil or control voltage, mounting style, environment, validation quantity and expected production volume.
Mercury Wetted Relay HGSR English catalog
Review the standardized English product-family catalog, datasheets and RFQ path for this product category.
Download Category Catalog Complete Product Catalog Request Engineering Quote
Generated by SHR AUTOSENSOR TECH LIMITED for public English reference. Final ratings, drawings and application suitability are confirmed by RFQ.
Showing 10–18 of 20 results
-

HGSR05-1A04
$60.00 View / Buy -

HGSR05-1C
$60.00 View / Buy -

HGSR05-2A04
$60.00 View / Buy -

HGSR12-1A04
$60.00 View / Buy -

HGSR12-1C
$60.00 View / Buy -

HGSR24-1A04
$60.00 View / Buy -

HGSR24-1C
$60.00 View / Buy -

MERCURY-WETTED-RELAY-HGSR-SERIES
$60.00 View / Buy -
Sale!

SPDT Form C 12V Mercury Wetted Relay with Shell HGSR12-1C04