MiRelay

8KV Reed Relay

Browse MiRelay relay, contactor, and sensor series. For pricing, samples, or cross-reference support, send your specifications.

Request Quote Cross Reference

Product family overview

8KV Reed Relay application and selection guide

High voltage reed relays use hermetically sealed reed switches and insulation-optimized packaging for low-level, test and instrumentation switching where switching voltage, stand-off voltage and dielectric ratings must be checked separately.

Select this family when the design needs compact high-voltage switching, low leakage, clean signal isolation and repeatable switching in test or instrumentation systems.

Semiconductor ATE and wafer probe switchingMedical high-voltage diagnostic equipmentCable / insulation / hipot test systemsPrecision instrumentation and high-voltage multiplexing
High Voltage Reed Relay principle illustration
1High-voltage input
2Hermetic reed switch
3Insulated relay package
4ATE / medical / HV output
Main parameters

Key selection parameters

Voltage classes
4kV / 6kV / 10kV / 15kV / 20kV series
Contact forms
1 Form A and series-dependent options
Coil options
Model-specific coil voltage; confirm by datasheet/RFQ
Insulation focus
High dielectric strength and low leakage signal switching
Mounting
PCB relay, module and custom high-voltage assembly options
Engineering selection notes

Before choosing a model

These notes keep product pages useful for engineers while avoiding overclaims. Final ratings remain model- and application-specific.

Separate switching, stand-off and dielectric ratingsSwitching voltage is the voltage the relay may open or close under specified load. Stand-off/hold-off and dielectric ratings are withstand tests and should not be treated as hot-switching capability.
Dry reed relays are low-bounce, not universally zero-bounceUse model datasheets for operate time and bounce behavior. Reserve bounce-free language for mercury wetted contacts or explicitly specified designs.
Load type controls lifeCapacitive inrush, inductive energy and hot-switching conditions can reduce contact life. Confirm load type, duty cycle and safety margin through datasheet review and RFQ.
Series comparison

High voltage reed relay series comparison

Use the voltage class as the first filter, then confirm coil voltage, contact form, carry current, package and insulation details on the individual model page.

Voltage classTypical useSelection focusModel page confirms
4kVCompact high-voltage signal switchingSmall footprint, relay density and low leakageCoil voltage, contact form, switching current and package
6kVATE and instrumentation switching above standard relay voltageDielectric strength and channel densityBreakdown voltage, carry current and contact material
10kVHipot, medical and precision HV test switchingSafety margin, insulation path and switching currentCoil data, tungsten contact options and timing
15kVHigher isolation test matrices and HV measurementCreepage/clearance, package and load profileDimensions, dielectric rating and mounting style
20kVSpecialized HV test and instrumentation platformsMaximum isolation requirement and custom assembly optionsDatasheet limits, RFQ application review and sample validation
Model display

Representative models in this family

Each model links to its own detail page and datasheet/RFQ path. Use the All Models index for the complete list.

HRM05-2A08-HCHRM05-2A08-HC High Voltage Reed Relay Module
  • Voltage classes: 4kV / 6kV / 10kV / 15kV / 20kV series
  • Contact forms: 1 Form A and series-dependent options
  • Coil options: Model-specific coil voltage; confirm by datasheet/RFQ
  • Insulation focus: High dielectric strength and low leakage signal switching

Details · Datasheet

HRM12-2A08-HCHRM12-2A08-HC High Voltage Reed Relay Module
  • Voltage classes: 4kV / 6kV / 10kV / 15kV / 20kV series
  • Contact forms: 1 Form A and series-dependent options
  • Coil options: Model-specific coil voltage; confirm by datasheet/RFQ
  • Insulation focus: High dielectric strength and low leakage signal switching

Details · Datasheet

HRM24-2A08-HCHRM24-2A08-HC High Voltage Reed Relay Module
  • Voltage classes: 4kV / 6kV / 10kV / 15kV / 20kV series
  • Contact forms: 1 Form A and series-dependent options
  • Coil options: Model-specific coil voltage; confirm by datasheet/RFQ
  • Insulation focus: High dielectric strength and low leakage signal switching

Details · Datasheet

HVR05-1A08-06-HCHVR05-1A08-06-HC High Voltage Reed Relay
  • Voltage classes: 4kV / 6kV / 10kV / 15kV / 20kV series
  • Contact forms: 1 Form A and series-dependent options
  • Coil options: Model-specific coil voltage; confirm by datasheet/RFQ
  • Insulation focus: High dielectric strength and low leakage signal switching

Details · Datasheet

HVR12-1A08-02-HCHVR12-1A08-02-HC High Voltage Reed Relay
  • Voltage classes: 4kV / 6kV / 10kV / 15kV / 20kV series
  • Contact forms: 1 Form A and series-dependent options
  • Coil options: Model-specific coil voltage; confirm by datasheet/RFQ
  • Insulation focus: High dielectric strength and low leakage signal switching

Details · Datasheet

HVR12-1A08-06-HCHVR12-1A08-06-HC High Voltage Reed Relay
  • Voltage classes: 4kV / 6kV / 10kV / 15kV / 20kV series
  • Contact forms: 1 Form A and series-dependent options
  • Coil options: Model-specific coil voltage; confirm by datasheet/RFQ
  • Insulation focus: High dielectric strength and low leakage signal switching

Details · Datasheet

HVR12-1A08-P11HVR12-1A08-P11 High Voltage Reed Relay
  • Voltage classes: 4kV / 6kV / 10kV / 15kV / 20kV series
  • Contact forms: 1 Form A and series-dependent options
  • Coil options: Model-specific coil voltage; confirm by datasheet/RFQ
  • Insulation focus: High dielectric strength and low leakage signal switching

Details · Datasheet

HVR12-1B08-06-HCHVR12-1B08-06-HC High Voltage Reed Relay
  • Voltage classes: 4kV / 6kV / 10kV / 15kV / 20kV series
  • Contact forms: 1 Form A and series-dependent options
  • Coil options: Model-specific coil voltage; confirm by datasheet/RFQ
  • Insulation focus: High dielectric strength and low leakage signal switching

Details · Datasheet

HVR12-2A08-01HVR12-2A08-01 High Voltage Reed Relay
  • Voltage classes: 4kV / 6kV / 10kV / 15kV / 20kV series
  • Contact forms: 1 Form A and series-dependent options
  • Coil options: Model-specific coil voltage; confirm by datasheet/RFQ
  • Insulation focus: High dielectric strength and low leakage signal switching

Details · Datasheet

HVR24-1A08-04-HCHVR24-1A08-04-HC High Voltage Reed Relay
  • Voltage classes: 4kV / 6kV / 10kV / 15kV / 20kV series
  • Contact forms: 1 Form A and series-dependent options
  • Coil options: Model-specific coil voltage; confirm by datasheet/RFQ
  • Insulation focus: High dielectric strength and low leakage signal switching

Details · Datasheet

HVR24-1A08-06-HCHVR24-1A08-06-HC High Voltage Reed Relay
  • Voltage classes: 4kV / 6kV / 10kV / 15kV / 20kV series
  • Contact forms: 1 Form A and series-dependent options
  • Coil options: Model-specific coil voltage; confirm by datasheet/RFQ
  • Insulation focus: High dielectric strength and low leakage signal switching

Details · Datasheet

HVR24-1A08-150-HCHVR24-1A08-150-HC High Voltage Reed Relay
  • Voltage classes: 4kV / 6kV / 10kV / 15kV / 20kV series
  • Contact forms: 1 Form A and series-dependent options
  • Coil options: Model-specific coil voltage; confirm by datasheet/RFQ
  • Insulation focus: High dielectric strength and low leakage signal switching

Details · Datasheet

View complete model index

FAQ

8KV Reed Relay selection FAQ

Answers are shown on-page to match the structured FAQ data and help engineers prepare datasheet review or RFQ requests.

How do I choose a 8KV Reed Relay model?

Start from the application requirement, then compare Voltage classes, Contact forms, Coil options, Insulation focus, Mounting. Open the model detail page and PDF datasheet before confirming the final ordering code.

Where can I find individual datasheets for this product family?

Each representative model card links to its own detail page and PDF datasheet. For production projects, submit an RFQ so voltage, current, mounting and compliance requirements can be confirmed.

What information should be included in an RFQ?

Include working voltage, current, load type, contact or output form, coil or control voltage, mounting style, environment, validation quantity and expected production volume.

English engineering resources

8KV Reed Relay English catalog

Review the standardized English product-family catalog, datasheets and RFQ path for this product category.

Download Category Catalog Complete Product Catalog Request Engineering Quote

Original source PDFs are preferred when available. Generated English PDFs are used only when no original source PDF is found; final ratings, drawings and application suitability are confirmed by RFQ.

WhatsApp Request a Quote