Description
HVR12-1A10-211 High Voltage Reed Relay for engineering selection. 12 VDC coil, 1 Form A contact, 7.5 kVDC switching, 50 W rating. Values are organized from the professional datasheet for engineering pre-selection. Confirm final switching load, insulation and footprint before order.

Technical specifications
| Nominal Coil Voltage | 12 VDC |
|---|---|
| Nominal Current | 60 mA |
| Coil Resistance | 200±10% Ω |
| Max Pull-in Voltage | 9 VDC |
| Min Drop-out Voltage | 1 VDC |
| Contact Form | 1 Form A |
| Max Contact Rating | 50 W |
| Max Switch Voltage | 7.5 kVDC |
| Max Switch Current | 3.0 A |
| Max Carrying Current | 5.0 A |
| Min Breakdown Voltage | 10 kVDC |
| Max Contact Resistance | 150 mΩ |
| Life Expectancy | 5×10^7 ops @500V 100mA |
| Dielectric Open / Contact-Coil | 10 / 15 kVDC |
| Insulation Open / Contact-Coil | 1×10^12 Ω each |
| Operate Time incl. Bounce | 3.0 ms |
| Reset Time | 1.5 ms |
| Capacitance | 1.0 pF across open switch |
| Vibration | 20 G, 10–2KHz 1.5mm |
| Shock | 50 G, 11ms half-sine |
| Operating Temperature | -20°C to +70°C |
| Storage Temperature | -35°C to +105°C |
| Soldering Temperature | 260°C, 5 sec max |
| Washability | Fully sealed |
Selection notes
- Separate switching voltage from dielectric/breakdown withstand voltage.
- Check contact form, coil drive and PCB/package outline before design-in.
- For HRM modules, confirm terminal wiring and panel/cabinet installation requirements.






Reviews
There are no reviews yet.