SHR AUTOSENSOR TECH LIMITED

HGFR05-1A

Technical product information for engineering review. Request datasheet, samples, pricing, lead time, or a cross-reference recommendation for this part.

Request Quote Cross Reference

HGFR05-1A

$60.00

Sample, Datasheet & Engineering Support

  • Model: HGFR05-1A
  • Purchase path: Buy sample online
  • Production projects: RFQ recommended for final electrical confirmation.

Download PDF DatasheetRequest Production QuoteSample Store

For faster support, include voltage/current, contact form, coil voltage, quantity and application.

SKU: HGFR05-1A Categories: ,
Model detail

HGFR05-1A product details, applications and specifications

Use this family where bounce performance and contact stability are more important than a general-purpose relay solution. Confirm orientation, regulatory and application limits before production use. The table below summarizes the key selection points; use the model datasheet for dimensions, ratings and ordering confirmation.

HGFR05-1A Mercury Wetted Relay product image
1Control coil
2Mercury wetted contact
3Stable low-resistance path
4Measurement / pulse output

Main specifications for RFQ

Public model
HGFR05-1A
Product family
Mercury Wetted Relays, Mercury Wetted Relay HGFR
Series
HGFR / HGMR / HGSR / HVR and related families
Switching behavior
Low bounce and stable contact resistance
Signal type
Precision signal, pulse and test switching
Orientation
Series-dependent; confirm mounting requirement by datasheet
Compliance note
Mercury handling/application suitability must be confirmed for the target market
Datasheet
Available as individual PDF for this model
Datasheet-style view

HGFR05-1A technical data by section

Grouped specification blocks make this model page easier to scan for engineering selection, RFQ review and sample validation.

Mechanical & mounting

Series
HGFR / HGMR / HGSR / HVR and related families
Switching behavior
Low bounce and stable contact resistance
Signal type
Precision signal, pulse and test switching

Ordering / RFQ notes

  • Confirm exact ordering code, coil voltage, contact form and termination style before purchase.
  • Share load voltage/current, load type, duty cycle, ambient temperature and isolation requirement in RFQ.
  • Use the linked PDF datasheet for package drawing, dimensions and final rating limits.
  • For mercury wetted relays, confirm required mounting orientation, mercury-related compliance and disposal rules for the target market.
  • Product family context: Mercury Wetted Relay.
Engineering selection notes

Avoid common specification mistakes

These notes keep product pages useful for engineers while avoiding overclaims. Final ratings remain model- and application-specific.

Orientation and compliance must be checkedMercury wetted relays are specialized precision parts. Many types require a defined mounting orientation and may be restricted by RoHS, WEEE, transport, disposal or customer environmental rules.
Bounce wording is contact-technology specificMercury wetted contacts are selected where extremely low or bounce-free switching is required. Do not apply this claim to dry reed relays unless an individual datasheet supports it.
Best fit: precision signal switchingUse mercury wetted types for low-level measurement, pulse/timing and data-acquisition circuits where contact stability is critical, not as a universal relay upgrade.

Typical applications

  • Precision test systems
  • Pulse and timing circuits
  • Instrumentation switching
  • Industrial measurement equipment

What to confirm before purchase

  • Voltage, current, load type and safety margin
  • Contact form, coil voltage and drive circuit
  • Mounting, wiring, environmental and compliance requirements
  • Sample validation quantity and production forecast
FAQ

HGFR05-1A ordering FAQ

These visible answers mirror the FAQ structured data and clarify what buyers should confirm before sample approval or production ordering.

What should be confirmed before ordering HGFR05-1A?

Confirm the exact ordering code, coil or control voltage, contact form or output type, voltage/current rating, mounting style, environmental conditions and validation quantity.

Is a PDF datasheet available for HGFR05-1A?

Yes. The model page links to an individual PDF datasheet for engineering review and RFQ confirmation.

What applications is this product family used for?

Precision test systems, Pulse and timing circuits, Instrumentation switching, Industrial measurement equipment.

Download HGFR05-1A Datasheet Request quote for this model Compare all models

English engineering resources

Datasheet, catalog and RFQ support

Download the newly generated English product datasheet, review the family catalog, or send application details for engineering confirmation.

Download English Datasheet Family Catalog Complete Catalog Request Engineering Quote

Generated by SHR AUTOSENSOR TECH LIMITED for public English reference. Final ratings, drawings and application suitability are confirmed by RFQ.

Reviews

There are no reviews yet.

Be the first to review “HGFR05-1A”

Your email address will not be published. Required fields are marked *


WhatsApp Request a Quote