Description
HRM05-6A10 High Voltage Reed Relay Module for engineering selection. 5 VDC coil, 6 Form A contact, 7 kV switching, 10 W rating. Values are organized from the professional datasheet for engineering pre-selection. Confirm final switching load, insulation and footprint before order.

Technical specifications
| Nominal | 5 VDC |
|---|---|
| Pickup | 4 VDC max |
| Dropout | 0.5 VDC min |
| Max voltage | 6.5 VDC |
| Resistance | 50 Ω |
| Contact Form | 6 Form A |
| Channels | 6 |
| Contact Rating | 10 W |
| Max Switching Voltage | 7 kV |
| Max Switching Current | 3.5 A |
| Max Carry Current | 5.0 A |
| Contact Resistance | 150 mΩ |
| Breakdown Voltage | 10 kVDC |
| Life Expectancy | 5×10^7 ops @ 500 VDC / 100 mA |
| Contact-to-Coil Dielectric | 15 kVDC |
| Insulation Resistance | 1×10^12 Ω |
| Operate Time | 3.0 ms |
| Release Time | 1.5 ms |
| Operating Temperature | -20°C to +70°C |
| Storage Temperature | -35°C to +105°C |
Selection notes
- Separate switching voltage from dielectric/breakdown withstand voltage.
- Check contact form, coil drive and PCB/package outline before design-in.
- For HRM modules, confirm terminal wiring and panel/cabinet installation requirements.






Reviews