SHR AUTOSENSOR TECH LIMITED

HVR24-1B10-150 High Voltage Reed Relay

Technical product information for engineering review. Request datasheet, samples, pricing, lead time, or a cross-reference recommendation for this part.

Request Quote Cross Reference

HVR24-1B10-150 High Voltage Reed Relay

$60.00

HVR24-1B10-150 High Voltage Reed Relay for engineering selection. 24 VDC coil, 1 Form B contact, 7.5 kVDC switching, 50 W rating.

Sample, Datasheet & Engineering Support

  • Model: HVR24-1B10-150
  • Purchase path: Buy sample online
  • Production projects: RFQ recommended for final electrical confirmation.

Download PDF DatasheetRequest Production QuoteSample Store

For faster support, include voltage/current, contact form, coil voltage, quantity and application.

Model detail

HVR24-1B10-150 product details, applications and specifications

Select this family when the design needs compact high-voltage switching, low leakage, clean signal isolation and repeatable switching in test or instrumentation systems. The table below summarizes the key selection points; use the model datasheet for dimensions, ratings and ordering confirmation.

HVR24-1B10-150 professional datasheet preview
High Voltage Reed Relay principle illustration
1High-voltage input
2Hermetic reed switch
3Insulated relay package
4ATE / medical / HV output

Main specifications for RFQ

Public model
HVR24-1B10-150
Product family
1KV Reed Relay, High Voltage Reed Relays, HVR High Voltage Reed Relays
Voltage classes
4kV / 6kV / 10kV / 15kV / 20kV series
Contact forms
1 Form A and series-dependent options
Coil options
Model-specific coil voltage; confirm by datasheet/RFQ
Insulation focus
High dielectric strength and low leakage signal switching
Mounting
PCB relay, module and custom high-voltage assembly options
Datasheet
Available as individual PDF for this model
Datasheet-style view

HVR24-1B10-150 technical data by section

Grouped specification blocks make this model page easier to scan for engineering selection, RFQ review and sample validation.

Electrical ratings

Voltage classes
4kV / 6kV / 10kV / 15kV / 20kV series

Coil / control data

Coil options
Model-specific coil voltage; confirm by datasheet/RFQ

Contact / output data

Contact forms
1 Form A and series-dependent options

Mechanical & mounting

Insulation focus
High dielectric strength and low leakage signal switching
Mounting
PCB relay, module and custom high-voltage assembly options

Ordering / RFQ notes

  • Confirm exact ordering code, coil voltage, contact form and termination style before purchase.
  • Share load voltage/current, load type, duty cycle, ambient temperature and isolation requirement in RFQ.
  • Use the linked PDF datasheet for package drawing, dimensions and final rating limits.
  • For reed relays, keep switching voltage, stand-off/hold-off voltage and dielectric strength separate during selection.
  • Product family context: High Voltage Reed Relay.
Engineering selection notes

Avoid common specification mistakes

These notes keep product pages useful for engineers while avoiding overclaims. Final ratings remain model- and application-specific.

Separate switching, stand-off and dielectric ratingsSwitching voltage is the voltage the relay may open or close under specified load. Stand-off/hold-off and dielectric ratings are withstand tests and should not be treated as hot-switching capability.
Dry reed relays are low-bounce, not universally zero-bounceUse model datasheets for operate time and bounce behavior. Reserve bounce-free language for mercury wetted contacts or explicitly specified designs.
Load type controls lifeCapacitive inrush, inductive energy and hot-switching conditions can reduce contact life. Confirm load type, duty cycle and safety margin through datasheet review and RFQ.

Typical applications

  • Semiconductor ATE and wafer probe switching
  • Medical high-voltage diagnostic equipment
  • Cable / insulation / hipot test systems
  • Precision instrumentation and high-voltage multiplexing

What to confirm before purchase

  • Voltage, current, load type and safety margin
  • Contact form, coil voltage and drive circuit
  • Mounting, wiring, environmental and compliance requirements
  • Sample validation quantity and production forecast
FAQ

HVR24-1B10-150 ordering FAQ

These visible answers mirror the FAQ structured data and clarify what buyers should confirm before sample approval or production ordering.

What should be confirmed before ordering HVR24-1B10-150?

Confirm the exact ordering code, coil or control voltage, contact form or output type, voltage/current rating, mounting style, environmental conditions and validation quantity.

Is a PDF datasheet available for HVR24-1B10-150?

Yes. The model page links to an individual PDF datasheet for engineering review and RFQ confirmation.

What applications is this product family used for?

Semiconductor ATE and wafer probe switching, Medical high-voltage diagnostic equipment, Cable / insulation / hipot test systems, Precision instrumentation and high-voltage multiplexing.

Download HVR24-1B10-150 Datasheet Request quote for this model Compare all models

English engineering resources

Datasheet, catalog and RFQ support

Download the original source datasheet when available; otherwise use the checked generated English datasheet, family catalog, or RFQ path.

Download English Datasheet Family Catalog Complete Catalog Request Engineering Quote

Original source PDFs are preferred when available. Generated English PDFs are used only when no original source PDF is found; final ratings, drawings and application suitability are confirmed by RFQ.

Description

HVR24-1B10-150 High Voltage Reed Relay for engineering selection. 24 VDC coil, 1 Form B contact, 7.5 kVDC switching, 50 W rating. Values are organized from the professional datasheet for engineering pre-selection. Confirm final switching load, insulation and footprint before order.

SeriesHVR
Withstand10 kV
Coil24 VDC
Contact1 Form B
HVR24-1B10-150 professional datasheet preview

Technical specifications

Nominal Coil Voltage 24 VDC
Nominal Current 40 mA
Coil Resistance 600±10% Ω
Max Pull-in Voltage 18 VDC
Min Drop-out Voltage 2 VDC
Contact Form 1 Form B
Max Contact Rating 50 W
Max Switch Voltage 7.5 kVDC
Max Switch Current 3.0 A
Max Carrying Current 5.0 A
Min Breakdown Voltage 10 kVDC
Max Contact Resistance 150 mΩ
Life Expectancy 5×10^7 ops @500V 100mA
Dielectric Open / Contact-Coil 10 / 15 kVDC
Insulation Open / Contact-Coil 1×10^12 Ω each
Operate Time incl. Bounce 2.0 ms
Reset Time 2.0 ms
Capacitance 1.0 pF across open switch
Vibration 20 G, 10–2KHz 1.5mm
Shock 50 G, 11ms half-sine
Operating Temperature -20°C to +70°C
Storage Temperature -35°C to +105°C
Soldering Temperature 260°C, 5 sec max
Washability Fully sealed

Selection notes

  • Separate switching voltage from dielectric/breakdown withstand voltage.
  • Check contact form, coil drive and PCB/package outline before design-in.
  • For HRM modules, confirm terminal wiring and panel/cabinet installation requirements.

Reviews

There are no reviews yet.

Be the first to review “HVR24-1B10-150 High Voltage Reed Relay”

Your email address will not be published. Required fields are marked *


WhatsApp Request a Quote