Description
HVR12-2A03-04 High Voltage Reed Relay for engineering selection. 12 VDC coil, 2 Form A contact, 1 kV ACpeak/DC switching, 100 W rating. Values are organized from the professional datasheet for engineering pre-selection. Confirm final switching load, insulation and footprint before order.

Technical specifications
| Nominal Coil Voltage | 12 VDC |
|---|---|
| Max Operating Voltage | 16 VDC |
| Coil Resistance | 445 Ω |
| Max Pull-in Voltage | 9 VDC |
| Min Drop-out Voltage | 1 VDC |
| Contact Form | 2 Form A |
| Max Contact Rating | 100 W |
| Max Switch Voltage | 1 kV ACpeak/DC |
| Max Switch Current | 1.0 A |
| Max Carrying Current | 2.5 A |
| Min Breakdown Voltage | 3 kVDC |
| Max Contact Resistance | 120 mΩ |
| Life Expectancy | Not specified in source |
| Dielectric Coil / Contact | 2 kVDC |
| Insulation Coil / Contact | 1×10^12 Ω |
| Operate Time incl. Bounce | 1.1 ms |
| Reset Time | 0.1 ms |
| Capacitance | 0.4 pF across contacts |
| Operating Temperature | -20°C to +70°C |
| Storage Temperature | -35°C to +105°C |
| Soldering Temperature | 260°C, 5 sec max |
Selection notes
- Separate switching voltage from dielectric/breakdown withstand voltage.
- Check contact form, coil drive and PCB/package outline before design-in.
- For HRM modules, confirm terminal wiring and panel/cabinet installation requirements.






Reviews