Description
HRM12-2C01 High Voltage Reed Relay Module for engineering selection. 12 VDC coil, 2 Form C contact, 240 V switching, 10 W rating. Values are organized from the professional datasheet for engineering pre-selection. Confirm final switching load, insulation and footprint before order.

Technical specifications
| Nominal | 12 VDC |
|---|---|
| Pickup | 9 VDC max |
| Dropout | 1 VDC min |
| Max voltage | 15 VDC |
| Resistance | 200 Ω |
| Contact Form | 2 Form C |
| Channels | 2 |
| Contact Rating | 10 W |
| Max Switching Voltage | 240 V |
| Max Switching Current | 4.0 A |
| Max Carry Current | 4.0 A |
| Contact Resistance | 200 mΩ |
| Breakdown Voltage | 1 kVDC |
| Life Expectancy | 5×10^7 ops @ 500 VDC / 100 mA |
| Contact-to-Coil Dielectric | 10 kVDC |
| Insulation Resistance | 1×10^9 Ω |
| Operate Time | 4.5 ms |
| Release Time | 4.0 ms |
| Operating Temperature | -20°C to +70°C |
| Storage Temperature | -35°C to +105°C |
Selection notes
- Separate switching voltage from dielectric/breakdown withstand voltage.
- Check contact form, coil drive and PCB/package outline before design-in.
- For HRM modules, confirm terminal wiring and panel/cabinet installation requirements.