Description
MH12-1A8K Mercury Wetted Reed Relay for engineering selection. Coil 12 VDC. 1 Form A contact. 5KV ACpeak/DC switching. 100 W rating. Values are organized from the professional datasheet for engineering pre-selection. Confirm final switching load, insulation and footprint before order.

Technical specifications
| Nominal coil voltage | 12 VDC |
|---|---|
| Max Operating voltage | 16 VDC |
| Max Pull-in voltage | 9 VDC |
| Min Drop-out voltage | 1.2 VDC |
| Coil Resistance | 200 ohm |
| Min Breakdown Voltage | 8K VDC |
| Contact Form | 1 Form A |
| Max Contact Rating | 100 W |
| Max Switch Voltage | 5KV ACpeak/DC |
| Max Switch Current | 5.0 A |
| Max Carrying Current | 10.0 A |
| Max Contact Resistance | 100 mohm |
| Dielectric Strength coil/contact | 8K VDC |
| Operate Time | 7.0ms |
| Reset Time | 5.0ms |
| Capacitance Across Contacts | 1.0pF |
| Storage Temperature | -35~+105℃ |
| Operating Temperature | -20~+70℃ |
| Soldering Temperature | 5 sec.max 260℃ |
Selection notes
- Separate switching voltage from dielectric/breakdown withstand voltage.
- Check contact form, coil drive and PCB/package outline before design-in.
- For HRM modules, confirm terminal wiring and panel/cabinet installation requirements.





Reviews