SHR AUTOSENSOR TECH LIMITED Engineering RFQ Support

HVMR12-1A001

Technical product information for engineering review. Request datasheet, samples, pricing, lead time, or a cross-reference recommendation for this part.

Request Quote Cross Reference

HVMR12-1A001

$60.00

HVMR12-1A001, SHR AUTOSENSOR HVMR series reed relay / component for test & measurement, industrial controls and semiconductor / high-voltage systems. Electrical specifications follow the series datasheet; an engineering RFQ is available on request.

Sample, Datasheet & Engineering Support

  • Model: HVMR12-1A001
  • Purchase path: Buy sample online
  • Production projects: RFQ recommended for final electrical confirmation.

Request Production QuoteSample Store

Primary path is RFQ. Use Buy Sample only for engineering validation quantities.

Buy Sample

Shipping included · In stock · Ships within 72 hours

SKU: HVMR12-1A001 Category:
Model detail

HVMR12-1A001 product details, applications and specifications

Select this family when the design needs compact high-voltage switching, low leakage, clean signal isolation and repeatable switching in test or instrumentation systems. The table below summarizes the key selection points; use the model datasheet for dimensions, ratings and ordering confirmation.

HVMR12-1A001
High Voltage Reed Relay principle illustration
1High-voltage input
2Hermetic reed switch
3Insulated relay package
4ATE / medical / HV output

Main specifications for RFQ

Public model
HVMR12-1A001
Product family
HVFR High Voltage Reed Relays
Voltage classes
4kV / 6kV / 10kV / 15kV / 20kV series
Contact forms
1 Form A and series-dependent options
Coil options
Model-specific coil voltage; confirm by datasheet/RFQ
Insulation focus
High dielectric strength and low leakage signal switching
Mounting
PCB relay, module and custom high-voltage assembly options
Datasheet
On request; send RFQ for confirmation
Datasheet-style view

HVMR12-1A001 technical data by section

Grouped specification blocks make this model page easier to scan for engineering selection, RFQ review and sample validation.

Electrical ratings

Voltage classes
4kV / 6kV / 10kV / 15kV / 20kV series

Coil / control data

Coil options
Model-specific coil voltage; confirm by datasheet/RFQ

Contact / output data

Contact forms
1 Form A and series-dependent options

Mechanical & mounting

Insulation focus
High dielectric strength and low leakage signal switching
Mounting
PCB relay, module and custom high-voltage assembly options

Ordering / RFQ notes

  • Confirm exact ordering code, coil voltage, contact form and termination style before purchase.
  • Share load voltage/current, load type, duty cycle, ambient temperature and isolation requirement in RFQ.
  • Ask sales for the latest PDF datasheet and drawing before sample approval.
  • For reed relays, keep switching voltage, stand-off/hold-off voltage and dielectric strength separate during selection.
  • Product family context: High Voltage Reed Relay.
Engineering selection notes

Avoid common specification mistakes

These notes keep product pages useful for engineers while avoiding overclaims. Final ratings remain model- and application-specific.

Separate switching, stand-off and dielectric ratingsSwitching voltage is the voltage the relay may open or close under specified load. Stand-off/hold-off and dielectric ratings are withstand tests and should not be treated as hot-switching capability.
Dry reed relays are low-bounce, not universally zero-bounceUse model datasheets for operate time and bounce behavior. Reserve bounce-free language for mercury wetted contacts or explicitly specified designs.
Load type controls lifeCapacitive inrush, inductive energy and hot-switching conditions can reduce contact life. Confirm load type, duty cycle and safety margin through datasheet review and RFQ.

Typical applications

  • Semiconductor ATE and wafer probe switching
  • Medical high-voltage diagnostic equipment
  • Cable / insulation / hipot test systems
  • Precision instrumentation and high-voltage multiplexing

What to confirm before purchase

  • Voltage, current, load type and safety margin
  • Contact form, coil voltage and drive circuit
  • Mounting, wiring, environmental and compliance requirements
  • Sample validation quantity and production forecast
FAQ

HVMR12-1A001 ordering FAQ

These visible answers mirror the FAQ structured data and clarify what buyers should confirm before sample approval or production ordering.

What should be confirmed before ordering HVMR12-1A001?

Confirm the exact ordering code, coil or control voltage, contact form or output type, voltage/current rating, mounting style, environmental conditions and validation quantity.

Is a PDF datasheet available for HVMR12-1A001?

The latest datasheet should be requested through RFQ before sample approval or production use.

What applications is this product family used for?

Semiconductor ATE and wafer probe switching, Medical high-voltage diagnostic equipment, Cable / insulation / hipot test systems, Precision instrumentation and high-voltage multiplexing.

Request quote for this model Compare all models

English engineering resources

Datasheet, catalog and RFQ support

Download the original source datasheet when available; otherwise use the checked generated English datasheet, family catalog, or RFQ path.

Family Catalog Complete Catalog Request Engineering Quote

Original source PDFs are preferred when available. Generated English PDFs are used only when no original source PDF is found; final ratings, drawings and application suitability are confirmed by RFQ.

Description

HVMR12-1A001

Mercury Wetted Reed Relay, 12 VDC coil

The HVMR12-1A001 is a mercury wetted reed relay with a 12 VDC coil. Mercury wetted contacts provide bounce-free switching with low and stable contact resistance over life, suited to high-reliability switching applications.

Key Highlights

  • Mercury wetted contacts: bounce-free switching
  • Low, stable contact resistance over life
  • High reliability for critical switching

Applications

  • Automatic test equipment (ATE)
  • High-reliability control systems
  • Test and measurement
  • Industrial electronics

Full electrical specifications for this exact model are not published in the currently linked datasheet. Please submit an RFQ to confirm coil ratings, contact ratings, and dimensions.

Reviews

There are no reviews yet.

Be the first to review “HVMR12-1A001”

Your email address will not be published. Required fields are marked *

WhatsApp Request a Quote