Description
HVR24-1C05 High Voltage Reed Relay for engineering selection. 24 VDC coil, 1 Form C contact, 2.5 kVDC switching, 100 W rating. Values are organized from the professional datasheet for engineering pre-selection. Confirm final switching load, insulation and footprint before order.

Technical specifications
| Nominal Coil Voltage | 24 VDC |
|---|---|
| Nominal Current | 40 mA |
| Coil Resistance | 600±10% Ω |
| Max Pull-in Voltage | 18 VDC |
| Min Drop-out Voltage | 2 VDC |
| Contact Form | 1 Form C |
| Max Contact Rating | 100 W |
| Max Switch Voltage | 2.5 kVDC |
| Max Switch Current | 3.0 A |
| Max Carrying Current | 3.2 A |
| Min Breakdown Voltage | 5 kVDC |
| Max Contact Resistance | 300 mΩ |
| Life Expectancy | 5×10^7 ops @500V 100mA |
| Dielectric Open / Contact-Coil | 5 / 10 kVDC |
| Insulation Open / Contact-Coil | 1×10^11 / 1×10^12 Ω |
| Operate Time incl. Bounce | 3.0 ms |
| Reset Time | 1.5 ms |
| Capacitance | 3.3 pF across open switch |
| Vibration | 20 G, 10–2KHz 1.5mm |
| Shock | 50 G, 11ms half-sine |
| Operating Temperature | -20°C to +70°C |
| Storage Temperature | -35°C to +105°C |
| Soldering Temperature | 260°C, 5 sec max |
| Washability | Fully sealed |
Selection notes
- Separate switching voltage from dielectric/breakdown withstand voltage.
- Check contact form, coil drive and PCB/package outline before design-in.
- For HRM modules, confirm terminal wiring and panel/cabinet installation requirements.






Reviews
There are no reviews yet.