Description
EVP-350 High Voltage DC Contactor for engineering selection. Coil 12/24 VDC. 1 Form A (SPST-NO) contact. Values are organized from the professional datasheet for engineering pre-selection. Confirm final switching load, insulation and footprint before order.
Technical specifications
| Nominal Coil Voltage | 12/24 VDC |
|---|---|
| Coil Power | Start 50W / Hold 5W |
| Contact Form | 1 Form A (SPST-NO) |
| Rated Switching Current | 350 A |
| Temporary Overcurrent (10 min) | 500 A |
| Temporary Overcurrent (1 min) | 650 A |
| Max Breaking Voltage | 1500 VDC |
| Max Breaking Capacity | 1000VDC, 2000A, 1 cycle |
| Contact Resistance | 0.4 mΩ |
| Electrical Endurance 100A/1500VDC make-break | 6000 ops |
| Electrical Endurance 200A/1500VDC break only | 2000 ops |
| Electrical Endurance 350A/1000VDC break only | 1000 ops |
| Dielectric, Open Main Contacts | 4400 VAC |
| Dielectric, Main Contact to Coil | 4400 VAC |
| Dielectric, Main to Aux Contacts | 4400 VAC |
| Dielectric, Open Aux Contacts | 800 VAC |
| Insulation Resistance @1000VDC | 10^9 ohm min |
| Operate Time max | 50 ms |
| Release Time max | 30 ms |
| Auxiliary Contact | 1 Form A, 3A/24VDC max, 10mA/24VDC min |
| Vibration Resistance | Sine, 10-2000Hz, 5G |
| Shock Resistance | 11ms 1/2 Sine, Peak 20G |
| Ambient Temperature | -40 to +85 C |
Selection notes
- Separate switching voltage from dielectric/breakdown withstand voltage.
- Check contact form, coil drive and PCB/package outline before design-in.
- For HRM modules, confirm terminal wiring and panel/cabinet installation requirements.







Reviews
There are no reviews yet.